Modbus TCP/IP Enhanced Communication Module, ProSoft
DESCRIPTIONS
-
inRAx® Enhanced Modbus TCP/IP Module, Communication Protocol: Modbus TCP/IP, Type Of Indicators: Configuration Status, Application Status, Backplane Connectivity Status, Module Status, Temperature Rating: 0 - 60 DEG C Operating, Environmental Conditions: Storage Temperature: -40 To 85 DEG C, Relative Humidity: 5 - 95% (Non-Condensing), Current Rating: 500 MA Max At 5 VDC Power Supply Distance Rating Of 4, Application: For scada and field device interface applications
SPECIFICATIONS
-
-
Item Name: Enhanced Modbus TCP/IP Module
-
Sub Brand: inRAx®
-
Communication Protocol: Modbus TCP/IP
-
Type Of Indicators: Configuration Status, Application Status, Backplane Connectivity Status, Module Status
-
Temperature Rating: 0 - 60 DEG C Operating
-
Environmental Conditions: Storage Temperature: -40 To 85 DEG C, Relative Humidity: 5 - 95% (Non-Condensing)
-
Current Rating: 500 MA Max At 5 VDC Power Supply Distance Rating Of 4
FEATURES
-
- Supports CompactLogix processors with 1769 I/O bus capability version 16 and greater (MicroLogix 1500 not supported)
- Add-on Instruction creates UDTs, providing logical definitions for I/O, status, and control data
- Add-on Profile support for RSLogix 5000 v.20 and greater, improving integration in the CompactLogix system
- Diagnostic data available in RSLogix 5000 controller tags, enabling decisions to be made based upon node health
- Module configuration backed up in CompactLogix project (ACD file)
- Module acts as a co-processor reducing impact to PLC scan time
- Supports up to 10,000 words of data
- Supports up to 20 Client and 20 Server connections simultaneously
- Floating point data movement supported, including configurable support for Enron, Daniel®, and other implementations
- ProSoft configuration builder
- I/O Size: 60/120/240 - 16 bit integers
- Debug Port: 10/100 Ethernet Port (auto-negotiating)
- Server Connections- 10 - MBAP Connections, 10 - Encapsulated Modbus Connections
- Configured commands can be controlled directly from ladder logic
- Configurable polling of command list, including continuous and on change of data
- Applications: For scada and field device interface applications
|